IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by others,
you must leave this manual—or a copy of it—with the end user.

TABLE OF CONTENTS

Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Mandatory Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Understanding the Indicator Lights and Alarm Horn Patterns . . . . . . . . .4
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
If You Suspect a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . .5
Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limitations of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Limited Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
All Rights Reserved. © 2004 BRK Brands, Inc.
BRK Brands Europe Ltd., Gordano Gate, Portishead, Bristol, BS20 7GG, UK
Customer Service Dept.: 01275 845024
E-mail address: sales@firstalert.co.uk

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters away
from children; 3) Store flammable materials in proper containers; 4) Keep
electrical appliances in good condition and dont overload electrical circuits;
5) Keep cookers, barbecue grills, fireplaces and chimneys grease- and
debris-free; 6) Never leave anything heating on the cooker unattended;
7) Keep portable heaters and open flames, like candles, away from flammable
materials; 8) Dont let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they
are not working properly. Smoke Alarms that do not work cannot alert you to a
fire. Keep at least one working fire extinguisher on every floor, and an addi-
tional one in the kitchen along with a fire blanket. Have fire escape ladders or
other reliable means of escape from an upper floor in case stairs are blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

IMPORTANT! Read Recommended Locations for Smoke Alarms and
Locations to Avoid for Smoke Alarms before beginning. This unit monitors
the air, and when smoke reaches its sensing chamber, it alarms. It can give
you more time to escape before fire spreads. This unit can ONLY give an
early warning of developing fires if it is installed, maintained and located
where smoke can reach it, and where all residents can hear it, as described
in this manual. This unit will not sense gas, heat, or flame. It cannot prevent
or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or mains powered? Different Smoke Alarms provide
different types of protection. See About Smoke Alarms for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on every
level of your home, in every bedroom, and in every bedroom hallway or
separate sleeping area. See Recommended Locations For Smoke
Alarms and Locations To Avoid For Smoke Alarms for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor. See
Limitations of Smoke Alarms for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family residence.
It alone may not meet requirements for boarding houses, sheltered housing,
hotels, motels, hostels, inns or communal escape routes in blocks of flats.
See Special Compliance Considerations for details.
1
All BRK
®
Smoke Alarms conform to regulatory requirements, including
BS5446: Pt. 1:2000 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionisation technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionisation
technology at detecting large particles, which tend to be produced in
greater amounts by smouldering fires, which may smoulder for hours
before bursting into flame. Sources of these fires may include cigarettes
burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.

USER’S MANUAL

SMOKE ALARMS

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where
the Smoke Alarm is installed before removing it from the mounting
bracket. Failure to turn off the power first may result in serious
electrical shock, injury or death.
This unit will not alert hearing impaired residents. It is recommend-
ed that you install special units which use devices like flashing
strobe lights to alert hearing impaired residents.
This unit must be powered by a 24-hour, 230VAC
pure sine wave
50Hz circuit. Be sure the circuit cannot be turned off by a switch,
dimmer, or ground fault circuit interrupter. Failure to connect this
unit to a 24-hour circuit may prevent it from providing constant
protection.
This Smoke Alarm must have AC or battery power to operate.
If the mains (AC) power fails, battery back-up will allow the alarm to
sound for at least 4 minutes. If mains (AC) power fails and the battery
is weak, protection should last for at least 30 days. If mains (AC)
power fails and the battery is dead or missing, the alarm cannot
operate.
Never disconnect the power from a mains (AC) powered unit to stop
an unwanted alarm. Doing so will disable the unit and remove your
protection. In the case of a true unwanted alarm open a window or
fan the smoke away from the unit. The alarm will reset automatically
when it returns to normal operation. Never remove the batteries
from a battery operated unit to stop an unwanted alarm (caused by
cooking smoke, etc.). Instead open a window or fan the smoke
away from the unit. The alarm will reset automatically.
Do not install the Alarm where it may be exposed to dripping
water or could be splashed.
Connect this unit ONLY to other compatible units. See How To
Install This Smoke Alarm for details. Do not connect it to any other
type of alarm or auxiliary device. Connecting anything else to this
unit may damage it or prevent it from operating properly.
On Model 7010BE Only:
This Smoke Alarm has a battery drawer
which resists closing unless a battery is installed. This warns you
the unit will not operate under DC power without a battery.
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn at
close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chambers and prevent the unit from operating properly.
AC Powered Photoelectric (Optical)
Smoke Alarm with Battery Back-Up
Model 7010BE
Input: 230V ~ , 50Hz, 0.05A
AC Powered Photoelectric (Optical)
Smoke Alarm with Lithium Battery
Back-Up
Model 7010LBE
Input: 230V ~ , 50Hz, 0.05A
BS5446: Pt. 1:2000
Licence No. 7960
US Patent 6,377,182

Bedienungsanleitung

Sehen Sie sich hier kostenlos das Handbuch für BRK 7010BE an. Dieses Handbuch fällt unter die Kategorie Rauchmelder und wurde von 2 Personen mit einem Durchschnitt von 9 bewertet. Dieses Handbuch ist in den folgenden Sprachen verfügbar: Englisch. Haben Sie eine Frage zum BRK 7010BE oder benötigen Sie Hilfe? Stellen Sie hier Ihre Frage

Brauchen Sie Hilfe?

Haben Sie eine Frage zum BRK 7010BE und die Antwort steht nicht im Handbuch? Stellen Sie hier Ihre Frage. Geben Sie eine klare und umfassende Beschreibung des Problems und Ihrer Frage an. Je besser Ihr Problem und Ihre Frage beschrieben sind, desto einfacher ist es für andere BRK 7010BE-Besitzer, Ihnen eine gute Antwort zu geben.

Anzahl der Fragen: 0

BRK 7010BE-Spezifikationen

Nachfolgend finden Sie die Produktspezifikationen und die manuellen Spezifikationen zu BRK 7010BE.

Allgemeines
Marke BRK
Model 7010BE
Produkte Rauchmelder
EAN 29054121011, 0029054121011
Sprache Englisch
Dateityp Benutzerhandbuch (PDF)
Technische Details
Entdeckertyp Optischer Melder
Interkonnektabel -
Übertragungstechnik -
Testknopf Ja
Lichtalarm Ja
Warnung Dezibel 85 dB
Produktfarbe Weiß
Leistung
Energiequelle AC
Akku-/Batteriespannung 9 V
Akku-/Batterietechnologie Alkali
Anzahl unterstützter Akkus/Batterien 1
Pufferbatterie Ja
Gewicht und Abmessungen
Durchmesser (mm) 127 mm
Höhe 48 mm
Breite 127 mm
Tiefe 127 mm
Gewicht 236 g
Betriebsbedingungen
Betriebstemperatur 5 - 38 °C
Temperaturbereich bei Lagerung 5 - 38 °C
Relative Luftfeuchtigkeit in Betrieb 10 - 85 %
Luftfeuchtigkeit bei Lagerung 10 - 85 %
Zertifikate
Zertifizierung EN 14604
Sonstige Funktionen
Verpackungsabmessungen (BxTxH) 130 x 130 x 60 mm
Verpackungsdaten
Paketgewicht 318 g
Mehr anzeigen

Häufig gestellte Fragen

Finden Sie die Antwort auf Ihre Frage nicht im Handbuch? Vielleicht finden Sie die Antwort auf Ihre Frage in den FAQs zu BRK 7010BE unten.

Ist Ihre Frage nicht aufgeführt? Stellen Sie hier Ihre Frage

Keine Ergebnisse