    WARNING:
    The information listed below must be followed
    during the installation, service, and operation
    of this unit. Unqualified individuals should
    not attempt to interpret these instructions or
    install this equipment. Failure to follow safety
    recommendations could result in possible
    damage to the equipment, serious personal
    injury or death.
    • The installer must comply with all local codes and
    regulations which govern the installation of this type
    of equipment. Local codes and regulations take
    precedence over any recommendations contained in
    these instructions. Consult local building codes and
    the National Electrical Code (ANSI CI) for special
    installation requirements.
    • Allelectricalwiringmustbecompletedinaccordance
    with local, state and national codes and regulations
    and with the National Electric Code (ANSI/NFPA 70)
    or in Canada the Canadian Electric Code Part 1 CSA
    C.22.1.
    • Thisequipmentcontainsliquidandgaseousrefrigerant
    under high pressure. DO NOT USE ANY PORTION OF
    THE CHARGE FOR PURGING OR LEAK TESTING.
    Installation or servicing should only be performed by
    qualified trained personnel thoroughly familiar with this
    type equipment.
    • Fullyannealed,refrigerantgradecoppertubingshould
    be used when installing the system. Refrigerant suction
    line tubing should be fully insulated.
    Installation of equipment may require brazing
    operations. Installer must comply with safety codes
    and wear appropriate safety equipment (safety glasses,
    work gloves, fire extinguisher, etc.) when performing
    brazingoperations.
    • Followallprecautionsintheliterature,ontags,and
    on labels provided with the equipment. Read and
    thoroughly understand the instructions provided with
    the equipment prior to performing the installation and
    operational checkout of the equipment.
    • Refrigerantandelectricallineshouldberoutedthrough
    suitably waterproofed openings to prevent water from
    leaking into the structure.
    IMPORTANT SAFETY INFORMATION
    INSTALLER: Please read all instructions before servicing
    this equipment. Pay attention to all safety warnings and
    any other special notes highlighted in the manual. Safety
    markings are used frequently throughout this manual to
    designate a degree or level of seriousness and should
    not be ignored.
    WARNING indicates a potentially hazardous situation
    that if not avoided, could result in personal injury or death.
    CAUTIONindicatesapotentiallyhazardoussituationthat
    if not avoided, may result in minor or moderate injury or
    property damage.
    WARNING:
    Shut off all electrical power to the unit before
    performing any maintenance or service on the
    system. Failure to comply may result in personal
    injury or death.
    WARNING:
    Unless noted otherwise in these instructions,
    only factory authorized parts or accessory
    kits may be used with this product. Improper
    installation, service, adjustment, or maintenance
    may cause explosion, fire, electrical shock or
    other hazardous conditions which may result
    in personal injury or property damage
    WARNING:
    S4BD Split System Air Conditioners are shipped
    charged with R410A refrigerant and ready
    for installation. If repairs make it necessary
    for evacuation and charging, it should only
    be attempted by qualified trained personnel
    thoroughly familiar with this equipment. Under
    no circumstances should the owner attempt to
    install and/or service this equipment. Failure to
    comply with this warning could result in property
    damage, personal injury, or death.
    CAUTION:
    This unit uses refrigerant R-410A. DO NOT use
    any other refrigerant in this unit. Use of another
    refrigerant will damage the unit.
Kelvinator JS4BD042KB

Brauchen Sie Hilfe?

Anzahl der Fragen: 0

Haben Sie eine Frage zum Kelvinator JS4BD042KB oder benötigen Sie Hilfe? Stellen Sie hier Ihre Frage. Geben Sie eine klare und umfassende Beschreibung des Problems und Ihrer Frage an. Je detaillierter Sie Ihr Problem und Ihre Frage angeben, desto einfacher können andere Kelvinator JS4BD042KB-Eigentümer Ihre Frage richtig beantworten.

Sehen Sie sich hier kostenlos das Handbuch für Kelvinator JS4BD042KB an. Dieses Handbuch fällt unter die Kategorie Klimaanlagen und wurde von 1 Personen mit einem Durchschnitt von 7.5 bewertet. Dieses Handbuch ist in den folgenden Sprachen verfügbar: Engels. Haben Sie eine Frage zum Kelvinator JS4BD042KB oder benötigen Sie Hilfe? Stellen Sie hier Ihre Frage

Kelvinator JS4BD042KB-Spezifikationen

Allgemeines
Marke Kelvinator
Model JS4BD042KB
Produkte Klimaanlage
Sprache Engels
Dateityp PDF

Häufig gestellte Fragen

Nachfolgend finden Sie die am häufigsten gestellten Fragen zu Kelvinator JS4BD042KB .

Ist Ihre Frage nicht aufgeführt? Stellen Sie hier Ihre Frage

Bedienungsanleitu.ng

Auf der Suche nach einer Bedienungsanleitung? Bedienungsanleitu.ng sorgt dafür, dass Sie in Windeseile die Bedienungsanleitung finden, die Sie suchen. In unserer Datenbank befinden sich mehr als 1 Million PDF Bedienungsanleitungen von über 10.000 Marken. Jeden Tag fügen wir die neuesten Bedienungsanleitungen hinzu, damit Sie jederzeit das Produkt finden, das Sie suchen. Es ist ganz einfach: Tippen Sie in der Suchleiste Markenname und Produkttyp ein und Sie können direkt die Bedienungsanleitung Ihrer Wahl gratis online einsehen.

Bedienungsanleitu.ng

© Copyright 2021 Bedienungsanleitu.ng. Alle Rechte vorbehalten.

Diese Website benutzen Cookies. Wenn Sie die Website weiter nutzen, stimmen Sie der Verwendung von Cookies zu.

Erfahren Sie mehr